File name E5061B LXI 1.3 component Update Procedure E5061B_LXI_readme [2].pdf Procedure for updating a LXI 1.3 component on the E5061B network analyzer This document describes the procedure for updating a software component of the LXI 1.3 installed on the E5061B network analyzer. If your E5061B's HDD Revision is EL200, KY200, EL203, KY203, or KY204, it is recommended to update the LXI component by following the procedure shown below. Updating this LXI component will ensure the system's stability in the long-term continuous operation (e.g. more than 24 hours), especially if additional software such as security software is installed and operated on the E5061B. E5061B's HDD Revision can be checked by pressing [System], Firmware Revision. HDD revision is shown at HDD image column. NOTE: Do not perform this LXI component update for the E5061B that has the HDD Revision of EL1xx. Contents of the compressed files - Setup.vbs Script for updating the LXI revision to 00.00.24 - AgilentLxiSetup.ms_ LXI component installation program, main body - Readme.pdf Updating procedure (this document) NOTE: The extension of "AgilentLxiSetup" was intentionally changed to "ms_" for this LXI component update. Do not change it to ".msi". Procedure 1. Update the E5061B's firmware revision to A.02.06 or above. The E5061B's firmware must be updated to revision A.02.06 or above before updating the LXI component. (If you have already updated your E5061B to A.02.06 or above, Skip this step and go to the step-2 "Exit the E5061B firmware".) 1-1) Download the E5061B firmware revision (A.02.06 or above) from the download site to your PC. It is prepared as a self-extracting file (E5061B_xx.xx.exe). 1-2) Run "E5061B_xx.xx.exe" to extract "E5061B.msi" on your PC, and copy it to the E5061B's D: drive. 1-3) On the E5061B, press [System], Service Menu, and Update Firmware. The password dialog box will appear. 1-4) Type e506xa as the password, and click OK. 1-5) Select "E5061.msi" in the D: drive, and press Open. The windows installer will appear. Follow the instruction of windows installer to install the firmware. After the installation is finished, the instrument will restart. 1-6) Press [System], and Firmware Revision to confirm the firmware revision. 2. Exit the E5061B firmware. Press [System], Service Menu, Exit, and select "OK" to finish running the E5061B firmware. 3. Update the LXI component to the new one. 2-1) Download "E5061B_LXI_0.0.24.exe" from the download site to your PC. It is prepared as a self-extracting file. 2-2) Run "E5061B_LXI_0.0.24.exe" to extract the following files. Update.vbs, AgilentLxiSetup.ms_, Readme.pdf 2-3) Copy "Update.vbs" and "AgilentLxiSetup.ms_" to the same folder location in the E5061B's D: drive (for example, to the root of the D: drive). 2-4) From My Computer, run the script program "Update.vbs" saved in the D: drive by double-clicking on it. This script program will automatically uninstall the old LXI component (Agilent ENA LXI Setup 00.00.19 or 00.00.20) and install the new LXI component (Agilent ENA LXI Se |
Date | User | Rating | Comment |